Interactive Set-Up
40 AX3000 - User's Manual
Double Touch Accuracy Range (pixels): this parameter defines a zone size
which allows double-click to be emulated. A double-click event will be sent
when the screen is touched twice (in a period less than 0.5 seconds) and when
the two impacts are located in the same zone (less than X pixels).
Note: the touch screen functions properly only after the calibration has been
performed.
After calibration touch screen events are automatically remapped to the
following mouse events:
- 5250 emulations: left double-click
- Other emulations or protocols: left click
3.3 - SETTING EACH SESSION
The AX3000’s built-in multi-connection capability allows simultaneous access to
up to 6 different servers on one or more Ethernet networks or by serial
connection.
Each independent session has:
- A connection: TCP/IP protocol and associated server
- A virtual terminal: emulation, function key values, number of lines, etc
Select the [Configuration]-[Sessions]-[Session X] menu (where X is the
session number). The "Session Type" list is displayed:
TSE (rdp)
Citrix (ica)
VNC
5250
3270
Text Emulation
None
Note: if the session was already associated with a "Session Type" the related
dialog box is displayed.